Pedestal Mounted Outdoor Enclosure: GasNet Style
The enclosure is fitted with night latch locking, barrels NOT Included. It has double doors with lift-off pintle hinges. Mounting Pedestal: Hot dipped galvanised mounting pedestal as per Gasnet Drawing No.SB5-1-2
Typical Finish: Bronze Olive or Anti-Graffiti powder coated, Velocity Green
Material: Typically 2mm body with a 6mm base, Mild Steel. Marine Grade Aluminium and Stainless steel are also available.
Features:
-
A segregated compartment with a supply / meter panel is included.
-
The rectifier will include, mains switch, RCD protection
-
24hr Time Clock, bypass Switch, a Normal / Interrupt Switch, Interrupter Socket
-
Spark Gap Protection, MOV Protection
-
Total volts Voltmeter
-
An Ammeter for each Output circuit
-
Total Amps Ammeter (optional)
-
Transformer / Rectifier, Neutral Bar and Earth Bar
-
Circuit Breakers will be provided for the output circuits and for secondary protection of the transformer.
-
PID Auto Controllers can be fitted to each output circuit (optional)
-
In Auto mode a PID controller monitors a ground reference and determines the required voltage to correct the difference between the reference and a set point value, quickly and efficiently. The output voltage is phase angle controlled. Auto mode helps deal with fluctuating ground potential due to changing climate conditions and other factors.
-
Manual mode maintains a manually set voltage in reference to the common anode via phase angle control. Eliminating the need for crude resistance links to create a desired voltage drop.
-
Impressed Current Cathodic Protection Rectifiers
CPR RANGE

CABINET DIMENSIONS

Floor Mount Enclosure
The enclosure is fitted with night latch locking, barrels NOT Included. It has a single door with lift-off pintle hinges. Enclosure will be base mounted with a Hot dipped galvanised plinth frame. Typical Finish: Bronze Olive or Anti-Graffiti powder coated, Velocity Green
Material: Typically 2mm body, Mild Steel. Marine Grade Aluminium and Stainless steel are also available.
Features:​
-
The rectifier will include, mains switch, RCD protection
-
24hr Time Clock, bypass Switch, a Normal / Interrupt Switch, Interrupter Socket
-
Spark Gap Protection, MOV Protection
-
Total volts Voltmeter
-
An Ammeter for each Output circuit
-
Total Amps Ammeter (optional)
-
Transformer / Rectifier, Neutral Bar and Earth Bar
-
Circuit Breakers will be provided for the output circuits and for secondary protection of the transformer.
-
PID Auto Controllers can be fitted to each output circuit (optional)
-
In Auto mode a PID controller monitors a ground reference and determines the required voltage to correct the difference between the reference and a set point value, quickly and efficiently. The output voltage is phase angle controlled. Auto mode helps deal with fluctuating ground potential due to changing climate conditions and other factors.
-
Manual mode maintains a manually set voltage in reference to the common anode via phase angle control. Eliminating the need for crude resistance links to create a desired voltage drop.
-
RATING
RATING
CABINET DIMENSIONS
SMV UNITS
Base Mounted Enclosure:
The enclosure is fitted with night latch locking, barrels NOT Included. Plinth mounted enclosure Anti Graffiti powder coat, Velocity Green, fitted with night latch locking, size 735H x 425Wx 320D. Plinth has internal gussetts for slab mounting. Fitted out with a distribution board consisting of Main Switch, Single Pole Circuit Breaker/ RCD, 2A, 240V, DP, 30mA, Double GPO, Jones Plug and MOV. Surge protection provided across MOV. Provision for mounting of Rectifier and supplied with rectifier as described below. Cubicle: 2mm Zincanneal, Galvanised Plinth.
Rectifier :
Switch mode power supply Type SMV24/2, infinitely adjustable 3 to 24V, 0.25 to 2A. Tested to AS/NZS2064 for conducted and radiated EMI.